Management Project Management

Pmi Standards Committee's A Guide to the Project Management Body of Knowledge PDF

By Pmi Standards Committee

The Interactive PMBOK(r) consultant positive aspects hypertext hyperlinks for simple reference.

Show description

Read Online or Download A Guide to the Project Management Body of Knowledge PDF

Best management: project management books

The Project Manager's Pocket Survival Guide by James Lewis PDF

I'm an skilled building undertaking supervisor, and that i rather loved this booklet, since it affirmed a few issues I already be aware of to be precise, and provided a few extra rules for me to think about, all written in a concise, sincere means. I defined it and acquired copied for my buddies to learn.

Read e-book online Managing a Modern Hospital PDF

Wellbeing and fitness care has develop into one in every of India's quickest turning out to be sectors long ago decade. a large number of personal gamers have entered this marketplace, combining to supply high quality future health care and repair in world-class hospitals and nursing houses all over the place India. it's been regarded expert method of sanatorium management and higher source allocation will move far to make sure either caliber and cost-effectiveness in wellbeing and fitness care in India.

Project Management Casebook Instructor's Manual - download pdf or read online

How do undertaking staff member get the information, abilities, and attitudes had to practice successfully? One confirmed technique is thru the case research process. The booklet deals 50 case stories that signify the breadth and value of undertaking administration and its influence at the daily administration of initiatives.

Additional info for A Guide to the Project Management Body of Knowledge

Sample text

The circuit breakers or fuses that are built into the generator are not sufficient to provide NEC required protection for the conductors from the generator to the PV system. An external (branch circuit rated) overcurrent device (and possibly a disconnect) must be mounted close to the generator. The conductors from the generator to this overcurrent device must have an ampacity of 115 percent of the name plate current rating of the generator [445-5]. Figure 18 show a typical one-line diagram for a system with a backup generator.

To minimize steady-state voltage drops, account for surge-induced voltage drops, and to increase system efficiency, most well-designed systems have conductors several sizes larger than required by the NEC . When the current-carrying conductors are 33 oversized, the equipment-grounding conductor must also be oversized proportionately [250-95]. , 12 and 24 volts from a 24-volt battery bank), the common negative conductor will carry the sum of all of the simultaneous load currents. The negative conductor must have an ampacity at least equal to the sum of all the amp ratings of the overcurrent devices protecting the positive conductors or have an ampacity equal to the sum of the ampacities of the positive conductors [690-8(c)].

Fuse Servicing Whenever a fuse is used for an overcurrent device and is accessible to unqualified persons, it must be in a circuit where all power can be removed from both ends of the fuse for servicing. It is not sufficient to reduce the current to zero before changing the fuse. There must be no voltage present on either end of the fuse prior to service. This may require the addition of switches on both sides of the fuse location-a complication that increases the voltage drop and reduces the reliability of the system [690-16, Diagram 690-l].